Cisco Ethernet/Token Ring Mixed Media Network Modules (archived)
Understanding Fast Ethernet LAN/WAN Interface Card Network Modules (archived)
Cisco NM-1FE1R2W Board
CR13 IN-RING LED
CR14 FDX LED
CR15 16 Mbps LED
CR16 LINK LED
CR17 FDX LED
CR18 100 Mbps LED
CR19 EN LED
F1 Fuse
J1 WIC Socket
J2 WIC Socket
J3 Unknown 10-pin pads
J5 5-pin header TR Status?
J6 DE9 Token Ring Port
J7 Token Ring RJ45 port
J8 Fast Ethernet RJ45 Port
|
P1 PCI Connector
T1 Pulse PE-67583 Transformer
T4 Bel 5558-5999-46 Transformer
U2 Xilinx XC9536
U6 Olicom 119000092
U8 AMD AM79C971AVC PCnet-FAST
U9 MT90863AG Rate Conversion Switch
U11 Xilinx XCS20XL
U15 TI TI380C60APAH
U17 17-50 33-02
U18 Siemens PEB20534
U19 Level One LXT970AQC FE Transceiver
U21 Xilinx Spartan XCS20
Y1 25 MHz osc
|
J5 appears to be a status port for Token
Ring. Note that pin 1 is towards the Pulse PE-67583 transformer!
1 |
2 |
3 |
4 |
5 |
6 |
+5 |
G |
DO |
DI |
CK |
MS |
Not sure of "MS", as the printing is over a PCB land.
Configuration
Each interface on the Cisco 2600/3600 series is configured as a slot/unit
number. Refer to
Overview of Cisco Network Modules
for more information on how to identify the slot numbers. On the Mixed Media
Network Module, the interfaces are addressed as seen in this list:
The Fast Ethernet interface is interface fastethernet
<slot>/0.
The Token Ring interface is interface tokenring
<slot>/0.
A serial WIC, a T1 CSU/DSU or a 56/64k channel service unit/data service
unit (CSU/DSU) WIC in slot W0 is interface serial
<slot>/0.
A BRI-S/T WIC or BRI-U WIC in slot W0 is interface bri
<slot>/0.
A serial WIC, a T1 CSU/DSU or a 56/64k CSU/DSU WIC in slot W1 is
interface serial <slot>/0 if slot W0 does not contain a serial
port (serial WIC or 56/64k CSU/DSU). If slot W0 has a serial WIC, the serial
WIC in slot W1 is interface serial <slot>/1.
A BRI-S/T WIC or BRI-U WIC in slot W1 is interface bri
<slot>/0 if slot W0 does not contain a BRI WIC. If slot W0 has a BRI
WIC, the BRI WIC in slot W1 is interface bri <slot>/1.
VWIC interfaces are E1 or T1 controllers. The controller number counts
from the lowest WIC slot and lowest controller on the VWIC. For example,
controller e1 <slot>/0.
|