Network Interface Standard or Draft |
Fiber cabling: ANSI X3.T9.5 UTP5 or S/UTP cabling: TP-PMD |
Bus Interface | available for ISA, EISA, MCA, PCI |
LAN Controller | AMD Supernet Chipset |
RAM | 128 KB static CMOS |
Power Consumption | @ 5 V max SAS approx. 2A.; DAS 2,65A @ 12 V max 50 mA. |
FLASH Memory | 128 KB (16 Pages à 8 KB) |
Dimensions | EISA: 275 mm x 127 mm (11 " x 5.08 "
approx.) ISA: 339 mm x 107 mm (13.8" x 4.28") MCA: 292 mm x 88,3 mm (11.5" x 3.48") PCI: 126 mm x 186 mm (4.98" x 7.4") |
Temperature Range | Storage: -20°C...+60°C / Operation: +10°C...+40°C |
Rel. Humidity (non-condensing) | Storage: 10%...90% / Operation: 30%...80% |
Unshielded Twisted Pair Port Pinouts (Port Type A, B, M and S)
The TP-PMD UTP standard uses RJ-45 connectors and receptacles.
The table
below summarizes the port pinouts.
RJ-45 Contact | Signal |
1 | Transmit (Tx+) |
2 | Transmit (Tx-) |
7 | Receive (Rx+) |
8 | Receive (Rx-) |
Note: Category 5 UTP cables for FDDI require 1<->7 and 2<->8 crossovers.