Error Codes 200 - 299

Important: Go HERE to learn how to decode the last two digits of the 200-range error codes to determine which memory module is at fault. (Applies to Models 56/57, 76/77, 85, and 90/95.)

Symptom / ErrorFRU / Action
0002 01XX / 0002 05XX
Reseat System Board Memory
1. System Board Memory
2. System Board
0002 0XXY / 0002 17XY
Memory Failure
If the 'Y' digit is in the range 'G' to 'V', suspect the model 90/95 processor board first.

See HERE how to decode the last two digits.

1. System Board Memory, Memory Riser Card (90), Processor Board (90/95)
2. System Board
0002 10XX / 0002 11XX
Check Memory
1. Processor Board (90/95)
2. System board Memory
3. Memory Riser Card (90)
4. System Board
0002 11CZ
Missing / unsupported Memory Module.
No module installed or one which does not provide the required Presence Detection coding.
1. Memory Module
2. System Board
3. 486SLC Processor Upgrade
See also Here!
0002 15UZ
No system memory is installed.
1. Memory Module
2. System Board
0002 14XX / 0002 15XX
0002 16XX / 0002 21XX
0002 26XX / 0002 40XX
0002 35XX / 0002 41XX
Check memory.
It might be the wrong type or wrong speed.
1. System Board Memory, Memory Riser Card (90)
2. System Board, Processor Board (90/95)
3. Bus Adapter
0002 21XX
ROM to RAM parity error
1. System Board
0002 31XX 1. Expanded Memory Option
0002 35XX
Single-Bit (correctable) ECC Memory error
1. Processor / System Board
2. System Board Memory
0002 4300 / 0002 4400 1. Processor Board (90/95)
0002 4500 / 0002 4600
Check memory
1. Processor Board
2. Memory Riser Card (90)
3. System Board
4. System Board Memory
0002 4700 1. Processor Board (90/95)
0002 51XX
Memory location changed on the memory expansion option
Information only
0002 52XX 1. Processor Board (90/95)
2. System Board
0002 5300 / 0002 5400 1. Processor Cache (90/95)
2. Processor Board
0002 55XX
Check Memory
1. System Board Memory
2. System Board
0002 6500 (thanks to Rick Ekblaw!)
LAN/A POST displays PRO11 error
1. Connect LAN/A to working network. (See LAN/A)
0002 9000
Unsupported memory combination detected
1. Correct the unsupported combination of ECC and parity memory modules. Run Automatic Configuration, then rerun Advanced Diagnostics
0002 91XX / 0002 92XX
0002 93XX / 0002 94XX
Checksum value mismatch
1. Run Automatic Configuration then rerun Advanced Diagnostics
0002 95XX / 0002 96XX
Check memory for an unsupported configuration or modules
1. System Board Memory
0002 9800
Checksum value mismatch
1. System Board Memory
Run Automatic Configuration then rerun Advanced Diagnostics
0002 XX00
Not listed above
1. 486DX33 Upgrade (70/80)