166XX/167XX Error Codes
Note:
The 5-digit error code begin with 166 if you are testing the PRIMARY adapter
or 167 if you are testing an ALTERNATE adapter.
Message |
Action |
16x80 Invalid testing mode
requested |
Restart the workstation. If problem remains replace the TR adapter. |
16x81 Primary adapter not
present at specified base I/O address |
Ensure unique base address is assigned to adapter. If a unique address
was used, restart the workstation. If problem remains replace the TR adapter. |
16x82 Alternate adapter not
present at specified base I/O address |
Ensure unique base address is assigned to adapter. If a unique address
was used, restart the workstation. If problem remains replace the TR adapter. |
16x85 Configuration compare
failure- adapter not present at specified base I/O address |
Ensure unique base address is assigned to adapter. If a unique address
was used, restart the workstation. If problem remains replace the TR adapter. |
16x90 Adapter Card Test failure |
Restart the workstation. If problem remains replace the TR adapter. |
16x91 Open Phase Test failure |
Restart the workstation. If problem remains, replace the TR adapter. |
16x92 Computer problem |
Run Advanced Diagnostics |
16x93 Transmit/Receive Test
failure The data recieved is not the same as the data sent |
Check to see that the network is connected properly. If the network
is connected correctly, restart the workstation. If problem remains, replace
the TR adapter. |
16x99 General error |
Restart the workstation. If problem remains, replace the TR adapter. |
AC-0040
0000 0000
AE-166
XX-0011
BU-XXXX
Field Appears
CE-0085
Field Appears
ET-00:00:02 (Our favorite for RPL without a network)
Field Stops Incrementing
OP-0000 XX
Field Appears flashing or is highlighted
PC-4020
Field Appears
RQ-XXXX
Field appears and XXXX is a value greater than 10
RS-XXXX
Field Appears
SF-XXXX
Field appears and XXXX is a value greater than 10.
|